Robertshaw Vibration Instruments can be used on rotating or
reciprocating machines. To select the proper instrument for your machine,
follow the link to Selection
Guide Matrix and/or follow the steps below.
-
Select the unit that meets the environmental conditions that your machine is
located in [hazardous area (explosion-proof or I.S.) or non-hazardous;
temperature range].
-
Select the power supply and/or remote reset voltage required.
-
Select the unit that provides you with the required measurement type, range and
frequency for your machine. The type would be acceleration (G's) or velocity
(IPS). The range would be the G range or IPS range. The frequency would be in
Hertz (RPM of machine ÷ 60).
-
If you require time delays (Start, Monitor or Start & Monitor delays – see
note below), select the instrument that offers that feature. Models
375A/376A series offer fixed time delays; Model 566 offers adjustable
Monitor Delay; Model 563A MUST BE used with Vibraswitch Model 366 or 365, and
provides adjustable time delay for the units that are connected to the
563A Monitor. If time delay is not required proceed to step 5 below.
-
Select the function that you desire:
-
Alarm or shut down only by:
-
Electrical SPDT or DPDT Switch Operation (Models 365/366, Models 375A/376A with
Start Delay Only).
-
Solid State Triac Switch Operation (Models 375A/376A except for Start Delay
ONLY Model which has SPDT Switch Contacts).
-
Pneumatic Operation (Model 368).
-
4-20 mADC output only (Models 570B/571A).
-
4-20 mADC output with alarm and/or shut down contacts, triac outputs (Model
566).
-
Check to see if the Model selected above has a mounting configuration suitable
for your application. All units are surface mount except for the following:
-
Models 570B/571A are stud mount.
-
Model 563A Monitor is used with the surface mount 365/366 Vibraswitches to
provide adjustable start and monitor time delays.
-
After you have made your selection, review the complete Product Specification
Sheet to verify your selection is correct.
NOTE:
Start, Monitor, or Start & Monitor Delays are used to prevent
unwanted shut down or alarm during start-up or normal operation of your
machine.
-
Start Delay: Prevents unwanted shut down when excessive vibration exists
(which exceeds the set-point of the vibration switch or monitor) during the
start-up of the machine.
-
Monitor Delay: Prevents unwanted shut down when short excessive
vibration spikes occur (which exceed the set-point of the vibration switch or
monitor) during normal operation of the machine. Spikes are typically caused by
detonation, cavitation, other machinery in the immediate area, etc.
|