RSW Logo
Search Contact Us Home Tank Level
About Products Tab What's new Sign-in Help
Single Point Controls
Multi-point Controls
Conductive Point Controls
Continuous Controls
Probes
Typical Applications
Selection Guide
Cross Reference

 

 

RF Level Head

Old Capacitance Equipment Cross Index to New

Model

General Description

Replace With

Series 42 Level-Log

Circular chart recorder with an internal 10 pf to 500 pf analog capacitance transmitter.

None

951-B Proximity Meter

Test equipment.

None

Level -Tek 101 – B

Remote (5 ft.) with lights, LLFS with no differential. Explosion-proof enclosure, Class II, Groups E, F & G.

304B, 310 or 5100

Level -Tek 101 – W

Same as 101-B, except weather-tight.

304B, 310 or 5100

Level -Tek 102 – B

Same as 101-B, except HLFS.

304B, 310 or 5100

Level -Tek 102– W

Same as 101-W, except HLFS.

304B, 310 or 5100

Level -Tek 1010 – E

Remote (5 ft.), with or without lights, no differential. Explosion-proof enclosure, Class I. Groups C & D, LLFS.

304B, 310 or 5100

Level -Tek 1020 - E

Same as 1010-E except HLFS.

304B, 310 or 5100

Any Level-Tek above with 'F' on end of number

Same as basic above, but with differential.

304B, 310 or 5100

Any Level-Tek above with 'T' on end of number

Same as basic above, but with time delay.

304B, 310 or 5100

Level -Tek 107 – W

Remote (5 ft.), hi-Sensitivity, LLFS with lights. Has some electronics on probe. Uses standard 3 wire cable. Weather-tight.

310 or 5100

Level -Tek 107 – E

Same as 107-W, except in explosion-proof enclosure, Class I, Groups C & D.

310 or 5100

Level -Tek 107 – B

Same as 107-E, except in explosion-proof enclosure, Class II, Groups E, F & G.

310 or 5100

Level -Tek 108 – W

Same as 107-W, except HLFS.

310 or 5100

Level -Tek 108 – E

Same as 107-E, except HLFS.

310 or 5100

Level -Tek 108 – B

Same as 107-B, except HLFS.

310 or 5100

Level -Set 111 – W

Capacitance transmitter with pneumatic 3 to 15 psi output. 6 pf span. Direct-acting. Weather-tight housing. LLFS.

167-A and 443A or 445A

Level -Set 111 – E

Same as 111-W, except in explosion-proof housing. Has adjustments through case.

167-A and 443A or 445A

Level -Set 111 – YE

Same as 111-W, except adjustments are internal.

167-A and 443A or 445A

Level -Set 112 – W

Same as 111-E, except HLFS.

167-A and 443A or 445A

Level -Set 112 – E

Same as 111-E, except HLFS.

167-A and 443A or 445A

Level -Set 112 – YE

Same as 111-YE, except HLFS.

167-A and 443A or 445A

Level -Tek 303A

Direct mounted, explosion-proof enclosure. 15 to 75 pf control range SPDT relay output.

304B and 318A

Level -Tek 304

Direct conversion to 304B.

304B

Level -Tek 304A

Direct conversion to 304B

304B

Level -Tek 305

Two-piece unit with detector mounted on probe and indicator remotely mounted. Adjustment range 10 to 100 pf.

304B, 310 or 5100

305 – A

Fixed, minimum differential.

304B, 310 or 5100

305 – F

Adjustable differential.

304B, 310 or 5100

305 – ( ) ( ) – W ( )

Weather-tight enclosure with red/#cccc99 lights.

310 or 5100

305 – ( ) ( )– N ( )

Explosion-proof enclosure with lights.

310 or 5100

305 – ( ) ( ) – M ( )

3x6 panel mount with single light.

310 or 5100

305 – ( ) ( ) – P ( )

3x6 panel mount with duplex lights.

310 or 5100

306 – A3 – W1

BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display (305 tight style with red/#cccc99 lights).

None

306 – A3 – W1 – T

Same as 306-A3-W1, except has a three (3) second time delay.

None

306 – A3 – N1

Same as 306-A3-W1, except explosion-proof display enclosure (305 style).

None

306 – A3 – N1 –T

Same as 306-A3-N1, except has a three (3) second time delay.

None

307 – W1

BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display. Has SPDT relay output. 0% to 2% BS & W detection.

None

307 – N1

Same as 307-W1, except display enclosure is explosion-proof.

None

308 –

BS & W measurement, continuous output monitor.

None

308 – A ( ) – ( ) ( )

1 to 5 mADC output.

None

308 – B ( ) – ( ) ( )

4 to 20 mADC output.

None

308 – C ( ) – ( ) ( )

10 to 50 mADC output.

None

308 – ( ) 1 – ( ) ( )

Weather-tight display (158A WT style).

None

308 – ( ) 2 – ( ) ( )

Explosion-proof display.

None

308 – ( ) 3 – ( ) ( )

Weather-tight display with time delay.

None

308 – ( ) ( ) – A ( )

0% to 5% span

None

308 – ( ) ( ) – B ( )

0% to 10% span

None

308 – ( ) ( ) – ( ) 1

2 in. pipe size.

None

308 – ( ) ( ) – ( ) 2

3 in. pipe size.

None

351A

Conductivity switch with 12 in. bare probe.

352 with 740-A1-A12

Level -Tel 154

Remote unit up to 200 ft. from probe using 50 ohm coaxial. Has some electronics in probe condulet. -W unit is weather-tight, -E unit is explosion-proof. Optional meters available, some with internal relays.

5000A, 7000 or 158A

Level -Tel 155

Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 3200 pf.

167, 210KB102, 5000A or 7000

Level -Tel 155 – B

3x6 display with one high alarm relay.

5000A or 7000

Level -Tel 155 – C

3x6 display with one low alarm relay.

5000A or 7000

Level -Tel 155 – D

3x6 display with two alarm relays.

5000A or 7000

Level -Tel 155 – E

Explosion-proof display, Class I Division 1, Groups C & D.

167 – X – 2

Level -Tel 155 – F

Weather-tight display (158A style).

167 – X – 2

Level -Tel 155 – G

3x6 display with no alarm.

167 – X – 2

Level -Tel 156

Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 2000 pf.

167, 210KB102, 5000A or 7000

156 – A ( )

1 to 5 mADC output.

None

156 – B ( )

4 to 20 mADC output.

167, 5000A or 7000

156 – C ( )

10 to 50 mADC output.

167or 5000A

156 – D ( )

0 to 4 mADC output.

None

156 – F ( )

Special.

Consult factory

156 – ( )1

Self-contained, probe mounted transmitter, blind, 120 VAC.

167 – B

156 – ( )2

Same as 156 -( )1 except 26.5 VDC transmitter.

167 – A

156 – ( )3

26.5 VDC transmitter with weather-tight display (158A style).

167 – A – 2

156 – ( )4

26.5 VDC transmitter with explosion-proof display.

167 – A – 2

156 – ( )5

26.5 VDC transmitter with 3x6 display.

167 – A – 2

156 – ( )6

26.5 VDC transmitter, 3x6 display with one alarm relay.

5000A

156 – ( )7

26.5 VDC transmitter, 3x6 display with two alarm relays.

5000A

157A

4-wire direct mounted analog transmitter.

167-B or C, 5000A or 7000

159

Anti-coat 4-wire remote transmitter.

158A, 5000A or 7000

160

Anti-coat 2-wire remote transmitter.

167-A

161

Remote Mounted transmitter with indicator. Has Anti-Coating circuitry

158A or 7000

162

4-wire dielectric compensation transmitter.

None

164

4-wire low-cost analog direct mounted transmitter.

167-B, C, or 5000A

165

Ultrasonic transmitter.

None

166

Submerence flow transmitter.

None

168

4-wire low-cost analog remote transmitter.

158A, 5000A or 7000

515

Controller for tilt probe

310, 5100 & 728B

900-600-304

Duplex detector for Model 162.

None

5001

Microprocessor-based on/off level detector with one DPDT relay.

5100

5002

Microprocessor-based on/off level detector with two DPDT relays.

5400A

5003

Microprocessor-based on/off level detector with three DPDT relays.

5400A

M5008

Multipoint Controller

None

Alliance Partners | Request Literature | Contact Us | Career Opportunities | Customer List
Centeron | RF Level Controls | Control Valves | Regulators | Vibration Controls | Pneumatic Controls
Site Map | Contact Us | FAQ