Model
|
General Description
|
Replace With
|
|
Series 42 Level-Log
|
Circular chart recorder with an internal 10 pf to 500 pf analog capacitance transmitter.
|
None
|
|
951-B Proximity Meter
|
Test equipment.
|
None
|
|
Level -Tek 101 – B
|
Remote (5 ft.) with lights, LLFS with no differential. Explosion-proof enclosure, Class II, Groups E, F & G.
|
304B, 310 or 5100
|
|
Level -Tek 101 – W
|
Same as 101-B, except weather-tight.
|
304B, 310 or 5100
|
|
Level -Tek 102 – B
|
Same as 101-B, except HLFS.
|
304B, 310 or 5100
|
|
Level -Tek 102– W
|
Same as 101-W, except HLFS.
|
304B, 310 or 5100
|
|
Level -Tek 1010 – E
|
Remote (5 ft.), with or without lights, no differential. Explosion-proof enclosure, Class I. Groups C & D, LLFS.
|
304B, 310 or 5100
|
|
Level -Tek 1020 - E
|
Same as 1010-E except HLFS.
|
304B, 310 or 5100
|
|
Any Level-Tek above with 'F' on end of number
|
Same as basic above, but with differential.
|
304B, 310 or 5100
|
|
Any Level-Tek above with 'T' on end of number
|
Same as basic above, but with time delay.
|
304B, 310 or 5100
|
|
Level -Tek 107 – W
|
Remote (5 ft.), hi-Sensitivity, LLFS with lights. Has some electronics on probe. Uses standard 3 wire cable. Weather-tight.
|
310 or 5100
|
|
Level -Tek 107 – E
|
Same as 107-W, except in explosion-proof enclosure, Class I, Groups C & D.
|
310 or 5100
|
|
Level -Tek 107 – B
|
Same as 107-E, except in explosion-proof enclosure, Class II, Groups E, F & G.
|
310 or 5100
|
|
Level -Tek 108 – W
|
Same as 107-W, except HLFS.
|
310 or 5100
|
|
Level -Tek 108 – E
|
Same as 107-E, except HLFS.
|
310 or 5100
|
|
Level -Tek 108 – B
|
Same as 107-B, except HLFS.
|
310 or 5100
|
|
Level -Set 111 – W
|
Capacitance transmitter with pneumatic 3 to 15 psi output. 6 pf span. Direct-acting. Weather-tight housing. LLFS.
|
167-A and 443A or 445A
|
|
Level -Set 111 – E
|
Same as 111-W, except in explosion-proof housing. Has adjustments through case.
|
167-A and 443A or 445A
|
|
Level -Set 111 – YE
|
Same as 111-W, except adjustments are internal.
|
167-A and 443A or 445A
|
|
Level -Set 112 – W
|
Same as 111-E, except HLFS.
|
167-A and 443A or 445A
|
|
Level -Set 112 – E
|
Same as 111-E, except HLFS.
|
167-A and 443A or 445A
|
|
Level -Set 112 – YE
|
Same as 111-YE, except HLFS.
|
167-A and 443A or 445A
|
|
Level -Tek 303A
|
Direct mounted, explosion-proof enclosure. 15 to 75 pf control range SPDT relay output.
|
304B and 318A
|
|
Level -Tek 304
|
Direct conversion to 304B.
|
304B
|
|
Level -Tek 304A
|
Direct conversion to 304B
|
304B
|
|
Level -Tek 305
|
Two-piece unit with detector mounted on probe and indicator remotely mounted. Adjustment range 10 to 100 pf.
|
304B, 310 or 5100
|
|
305 – A
|
Fixed, minimum differential.
|
304B, 310 or 5100
|
|
305 – F
|
Adjustable differential.
|
304B, 310 or 5100
|
|
305 – ( ) ( ) – W ( )
|
Weather-tight enclosure with red/#cccc99 lights.
|
310 or 5100
|
|
305 – ( ) ( )– N ( )
|
Explosion-proof enclosure with lights.
|
310 or 5100
|
|
305 – ( ) ( ) – M ( )
|
3x6 panel mount with single light.
|
310 or 5100
|
|
305 – ( ) ( ) – P ( )
|
3x6 panel mount with duplex lights.
|
310 or 5100
|
|
306 – A3 – W1
|
BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display (305 tight style with red/#cccc99 lights).
|
None
|
|
306 – A3 – W1 – T
|
Same as 306-A3-W1, except has a three (3) second time delay.
|
None
|
|
306 – A3 – N1
|
Same as 306-A3-W1, except explosion-proof display enclosure (305 style).
|
None
|
|
306 – A3 – N1 –T
|
Same as 306-A3-N1, except has a three (3) second time delay.
|
None
|
|
307 – W1
|
BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display. Has SPDT relay output. 0% to 2% BS & W detection.
|
None
|
|
307 – N1
|
Same as 307-W1, except display enclosure is explosion-proof.
|
None
|
|
308 –
|
BS & W measurement, continuous output monitor.
|
None
|
|
308 – A ( ) – ( ) ( )
|
1 to 5 mADC output.
|
None
|
|
308 – B ( ) – ( ) ( )
|
4 to 20 mADC output.
|
None
|
|
308 – C ( ) – ( ) ( )
|
10 to 50 mADC output.
|
None
|
|
308 – ( ) 1 – ( ) ( )
|
Weather-tight display (158A WT style).
|
None
|
|
308 – ( ) 2 – ( ) ( )
|
Explosion-proof display.
|
None
|
|
308 – ( ) 3 – ( ) ( )
|
Weather-tight display with time delay.
|
None
|
|
308 – ( ) ( ) – A ( )
|
0% to 5% span
|
None
|
|
308 – ( ) ( ) – B ( )
|
0% to 10% span
|
None
|
|
308 – ( ) ( ) – ( ) 1
|
2 in. pipe size.
|
None
|
|
308 – ( ) ( ) – ( ) 2
|
3 in. pipe size.
|
None
|
|
351A
|
Conductivity switch with 12 in. bare probe.
|
352 with 740-A1-A12
|
|
Level -Tel 154
|
Remote unit up to 200 ft. from probe using 50 ohm coaxial. Has some electronics in probe condulet. -W unit is weather-tight, -E unit is explosion-proof. Optional meters available, some with internal relays.
|
5000A, 7000 or 158A
|
|
Level -Tel 155
|
Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 3200 pf.
|
167, 210KB102, 5000A or 7000
|
|
Level -Tel 155 – B
|
3x6 display with one high alarm relay.
|
5000A or 7000
|
|
Level -Tel 155 – C
|
3x6 display with one low alarm relay.
|
5000A or 7000
|
|
Level -Tel 155 – D
|
3x6 display with two alarm relays.
|
5000A or 7000
|
|
Level -Tel 155 – E
|
Explosion-proof display, Class I Division 1, Groups C & D.
|
167 – X – 2
|
|
Level -Tel 155 – F
|
Weather-tight display (158A style).
|
167 – X – 2
|
|
Level -Tel 155 – G
|
3x6 display with no alarm.
|
167 – X – 2
|
|
Level -Tel 156
|
Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 2000 pf.
|
167, 210KB102, 5000A or 7000
|
|
156 – A ( )
|
1 to 5 mADC output.
|
None
|
|
156 – B ( )
|
4 to 20 mADC output.
|
167, 5000A or 7000
|
|
156 – C ( )
|
10 to 50 mADC output.
|
167or 5000A
|
|
156 – D ( )
|
0 to 4 mADC output.
|
None
|
|
156 – F ( )
|
Special.
|
Consult factory
|
|
156 – ( )1
|
Self-contained, probe mounted transmitter, blind, 120 VAC.
|
167 – B
|
|
156 – ( )2
|
Same as 156 -( )1 except 26.5 VDC transmitter.
|
167 – A
|
|
156 – ( )3
|
26.5 VDC transmitter with weather-tight display (158A style).
|
167 – A – 2
|
|
156 – ( )4
|
26.5 VDC transmitter with explosion-proof display.
|
167 – A – 2
|
|
156 – ( )5
|
26.5 VDC transmitter with 3x6 display.
|
167 – A – 2
|
|
156 – ( )6
|
26.5 VDC transmitter, 3x6 display with one alarm relay.
|
5000A
|
|
156 – ( )7
|
26.5 VDC transmitter, 3x6 display with two alarm relays.
|
5000A
|
|
157A
|
4-wire direct mounted analog transmitter.
|
167-B or C, 5000A or 7000
|
|
159
|
Anti-coat 4-wire remote transmitter.
|
158A, 5000A or 7000
|
|
160
|
Anti-coat 2-wire remote transmitter.
|
167-A
|
|
161
|
Remote Mounted transmitter with indicator. Has Anti-Coating circuitry
|
158A or 7000
|
|
162
|
4-wire dielectric compensation transmitter.
|
None
|
|
164
|
4-wire low-cost analog direct mounted transmitter.
|
167-B, C, or 5000A
|
|
165
|
Ultrasonic transmitter.
|
None
|
|
166
|
Submerence flow transmitter.
|
None
|
|
168
|
4-wire low-cost analog remote transmitter.
|
158A, 5000A or 7000
|
|
515
|
Controller for tilt probe
|
310, 5100 & 728B
|
|
900-600-304
|
Duplex detector for Model 162.
|
None
|
|
5001
|
Microprocessor-based on/off level detector with one DPDT relay.
|
5100
|
|
5002
|
Microprocessor-based on/off level detector with two DPDT relays.
|
5400A
|
|
5003
|
Microprocessor-based on/off level detector with three DPDT relays.
|
5400A
|
|
M5008
|
Multipoint Controller
|
None
|